Lesson 113 of 145
Timbre and sound experiments
Change one sound property at a time and relate the change to what you hear.
Your goal: Change one sound parameter while holding pitch and duration fixed; compare envelope, spectrum and listening observations.
Section 1 of 9
Hear how a sound begins and ends
Timbre helps distinguish sounds even when their pitch and duration match. Amplitude describes the size of the sound signal. The envelope describes how that size changes through time. A fast attack reaches its peak quickly; a slow attack grows toward it. Attack, decay, sustain and release are useful synthesis terms, but an acoustic sound need not have four neatly separated stages.
Below, the original tone lasts two seconds. In the guided task, select B and change only attack from 0.02 to 0.40 seconds. Select Listen, then compare A and B. Hear the slower onset while the pitch stays fixed. The envelope plot shows the changed rise.
First isolate attack with this separate 200 Hz model. Compare the quick and slow starts, keeping the harmonic mix fixed. The final workshop uses C4 and F4 instead.
The envelope shows how amplitude changes over time. Compare the two starts. The slow start takes longer to reach the same level; the frequencies stay the same.
The sound repeats until Stop.
Fundamental: 200 Hz · 5 ms per cycle
The slow start makes the bands darken gradually. This is a diagram of the example, not a microphone measurement.
Section 2 of 9
Practice: Hear how a sound begins and ends
Question 1 / 2
Attack changes from 0.02 to 0.40 seconds; pitch and total duration remain fixed. What should the envelope show?
Choose an answer, then select Check. Next question checks your answer before advancing.
Section 3 of 9
Compare the waveform and spectrum
A waveform plots amplitude against time. A spectrum shows energy or amplitude distributed across frequencies. Harmonics occur at integer multiples of a fundamental frequency. Real sounds can also have non-harmonic components and noise.
This model adds eight harmonic sine components. Its low-pass response reduces upper components more than lower ones. Reducing the cutoff from 4000 to 700 Hz leaves the fundamental frequency unchanged but changes the balance of harmonics. The waveform and spectrum therefore change. The time–frequency diagram combines spectral levels with the envelope; it is a diagram of the synthesized model, not a microphone measurement.
Compare the upper spectral bars before describing the sound as brighter or darker. AcousticsLab’s timbre module relates spectral distribution and changes through time to timbre.
Use this separate 200 Hz model to inspect spectral balance. Compare the original and strengthened second harmonic. The bars change while their frequency positions stay fixed. The workshop’s low-pass control instead reduces upper components; compare the direction of the change.
A body has frequencies at which it vibrates readily. Its strong response near one of these frequencies is resonance. An instrument body can strengthen some components. This example changes their balance; it does not copy a particular instrument.
The sound repeats until Stop.
Fundamental: 200 Hz · 5 ms per cycle
- 200 HzHarmonic 1
- 400 HzHarmonic 2
- 600 HzHarmonic 3
- 800 HzHarmonic 4
Longer bars mean greater amplitude. The mix is scaled to the same signal limit; that does not guarantee equal loudness.
Section 4 of 9
Practice: Compare the waveform and spectrum
Question 1 / 2
A low-pass change reduces upper harmonic bars while the fundamental remains. Which statement fits?
Choose an answer, then select Check. Next question checks your answer before advancing.
Section 5 of 9
Run a controlled comparison
For an attack comparison, keep the filter unchanged. For a filter comparison, restore the original attack first. Keep pitch, two-second duration and device volume fixed. The workshop matches A and B's RMS, a numerical measure of signal level over time. Equal measured levels do not guarantee equal perceived loudness: the envelope, spectrum and listener also matter.
Write a prediction, hear A and B, then describe an event you actually noticed. “B reaches its peak later” is an observation. “The attack setting caused that slower rise” is an explanation linked to the controlled change. If you hear little difference, report that honestly and inspect the plot.
Use the comparison matrix to choose a valid test before listening.
| Version | Attack | Filter cutoff | Pitch | Duration |
|---|---|---|---|---|
| A | 0.02 s | 4000 Hz | C4 | 2 s |
| B | 0.40 s | 4000 Hz | C4 | 2 s |
| C | 0.40 s | 700 Hz | C4 | 2 s |
A–B isolates attack. B–C isolates cutoff. A–C changes both, so it cannot isolate either cause.
Section 6 of 9
Practice: Run a controlled comparison
Question 1 / 2
A and B have equal pitch, duration and filter, but different attack. What can the comparison isolate?
Choose an answer, then select Check. Next question checks your answer before advancing.
Section 7 of 9
Describe a repeatable setup
Record your playback device, headphones or speakers, device volume setting and room conditions in the setup field. An audio interface connects compatible microphones or instruments to a computer; a phone can combine microphone, recorder and playback in one device. No extra equipment is required for this model comparison.
For an optional voice experiment, record the same short vowel twice on your own device. Change only microphone distance or the way you begin the vowel. Keep the room, phrase and level setting fixed; note the distance and any automatic gain processing. Replay the files locally. If your recorder changes gain automatically, include that limit in your explanation. This task does not need microphone access or an upload.
This setup log is an example, not a required equipment list.
| Item | Trial A | Trial B |
|---|---|---|
| Playback | Same headphones | Same headphones |
| Device volume | 30% | 30% |
| Room | Quiet room | Same room |
| Changed parameter | Reference | Attack only |
For an optional recording, add microphone distance and automatic-gain status. If the recorder changes gain between trials, the comparison has another variable.
Section 8 of 9
Practice: Describe a repeatable setup
Question 1 / 2
Which note makes a later comparison easier to reproduce?
Choose an answer, then select Check. Next question checks your answer before advancing.
Section 9 of 9
Apply the test to a different pitch
The independent example uses F4 instead of C4. Choose one parameter to change. Compare both tones at the same device volume; use the diagrams to support one observation and explain the controlled difference. Note your setup so a later comparison can use the same conditions.
The task checks that exactly one parameter changed and that you recorded your own review. It cannot verify what you heard or identify an acoustic instrument from this simplified sound.
Run a one-parameter sound experiment.
First compare A with B after changing only the attack from 0.02 to 0.4 seconds. Then restore the attack and try a lower cutoff.
The check confirms one controlled parameter change and completed fields. It does not judge whether your timbre description is true or whether the sound is better.
A stays at 0.02 seconds attack and 4000 Hz cutoff. Both versions last two seconds and use the same eight starting harmonics.
Reference sound
Select Listen. The two-second tone repeats until Stop. Changes enter at the next repeat. Keep your device volume fixed for the comparison.
These graphs show the synthesized model, not a microphone measurement. A and B have the same electrical RMS level; equal RMS does not guarantee equal perceived loudness.
Attack: 0.02 s
Cutoff: 4000 Hz
Read the spectrum values
- 1 · 261.6 Hz · 1.000
- 2 · 523.3 Hz · 0.500
- 3 · 784.9 Hz · 0.333
- 4 · 1046.5 Hz · 0.249
- 5 · 1308.1 Hz · 0.199
- 6 · 1569.8 Hz · 0.165
- 7 · 1831.4 Hz · 0.140
- 8 · 2093.0 Hz · 0.121
Both experiments and setup notes stay in this browser.
Reading progress…
Practice this topic
Instruments and timbres:Compare timbres